30 to 60 kVA Specificatons |
| |
Three Phase Input - Single Phase Output |
| Ups Rating KVA |
30 kVA |
40 kVA |
50 kVA |
60 kVA |
| Product Identification Number (PID No.) |
DHP E 30 |
DHP E 40 |
DHP E 50 |
DHP E 60 |
| Input (Rectifier) |
|
| Rectifier Input Voltage Range |
400 VAC 3 phase - 25 + 20% |
| Frequency range |
45-55 Hz |
| Phase |
Three Phase + Neutral + Earth (5 Wires) |
| Power Factor |
0.95 |
| Output (Inverter) |
|
| Voltage |
220/ 230 VAC |
| Voltage Regulation |
+/- 1 % |
| Frequency |
Automatic Synchronised tracking on utility power mode; 47 - 53 Hz, +/- 1 % on battery mode |
| Output Waveform |
Sine wave |
| Harmonic Distortion (THD) |
2 % (Linear Load) / 5 % (Non - Linear Load) |
| Voltage Transient (Dynamic Response) |
For 0-100% & 100-0 % Step load change the output shall remain within +/- 5% & recovers to the normal within 20 m sec. |
| Power Factor |
0.8 lag |
| Crest Factor |
3:1 |
| Efficiency (AC - AC) |
> 90% |
| Inverter Overload Capacity |
125% for 10 Minutes; 150% for 20 Seconds |
| Battery |
|
| Battery Type |
Sealed Maintenance Free Lead Acid, Lead Acid Tubular |
| DC Voltage |
192 V/ 360 V |
240 V/ 360 V |
240 V/ 360 V |
360 V |
| Charger |
Constant Voltage Constant Current Charger |
| Charger (Optional)* |
Intelligent MMBM Battery Management System using Multi- Modal Charging to enhance reliability and usage life of batteries. |
| Bypass |
Static Bypass/ Manual Maintenance Bypass
|
| Communication Interface |
|
| Standard |
RS 232 port for Software Interface |
| Optional (SNMP) |
SNMP network adapter interface for network management of power supply. |
| Optional (Remote Control - RS 485) |
Independent Digital Remote control at a distant of 1000 mts. supported by RS 485 for safe and convenient remote control |
| General |
|
| Operating Temperature |
0 Deg. to 40 Deg. C |
| Relative Humidity |
0 ~ 95% RH, Non Condensing |
| Noise Level |
< 60 dB @ 1meter |
| Indication |
Mains ON/ Faulty/ Inverter ON/ Faulty /Bypass Mode/ Battery Low/ No Load / System Fault |
| Display |
LCD Display to monitor Input Voltage, Battery Voltage, Charging Current, Discharge Current, Output Voltage, Output Frequency, Load Percentage, Bypass Voltage & Frequency |
| Audible Alarm |
Mains Failure Alarm, Low Battery Alarm, Overload and Over temperature |
| Protection |
Low Battery Protection, Overload Protection, Short circuit Protection, Output over voltage protection |
| Standards |
EN 50091-1 for Safety/ EN 50091-2 for EMC |
| Parallel function |
Available |